Siemens VRF10 and VRH10 Series valves are engineered for handling biogas, recovered gases, and compatible industrial process gases. Developed for integration into industrial gas trains, these valves can perform safety shutoff duties when paired with approved actuators in configurations that meet EN 161 requirements.
The valve range accommodates gases belonging to Gas Families I–III, air, and selected dry biogases or recycled gases with mildly aggressive properties. These products support gas distribution networks, industrial combustion installations, and gas recovery operations requiring dependable isolation and flow control.
Siemens VRF10 and VRH10 valves serve specialized gas handling and industrial processing requirements, including:
Actuator selection for VRF10 and VRH10 valves depends on the intended switching or regulation function and the chemical characteristics of the gas being handled.
Biogas and recycled process gases can contain different concentrations of chemically active substances depending on their origin. Constituents such as hydrogen sulfide (H2S), ammonia (NH3), and water vapor may affect valve materials, operating reliability, and service life.
Boonyium & Co., Ltd. offers technical consultation for industrial boilers, combustion equipment, and gas control components. Contact our specialists for assistance with Siemens VRF10 / VRH10 product information and choosing the appropriate valve configuration for your installation.
| Brand / Manufacturer | Siemens |
|---|---|
| Valve Series | VRF10 / VRH10 |
| Equipment Category | Valves for Biogas and Recycled Gas Applications |
| Operating Configuration | Two-port, Normally Closed |
| Safety Classification | Class A under EN 161 when paired with approved suitable actuators |
| EN 161 Valve Group | Group 2 (EN 161) |
| VRF10 Connection Range | DN40–DN80 |
| VRH10 Connection Range | DN80–DN125 |
| VRF10 Maximum Operating Pressure | Up to 600 mbar |
| VRH10 Permitted Operating Pressure | 250–300 mbar, model-dependent |
| Allowable Gas Temperature | 0 to +60°C |
| Ambient Working Temperature | -10 to +60°C |
| Permissible Storage Temperature | -20 to +60°C |
| Permissible Transport Temperature | -15 to +60°C |
| Humidity Limit | Below 95% RH; condensation is prohibited |
| Flange Pressure Rating | PN16 in accordance with ISO 7005-2 |
| Permitted Gas Categories | Gas Families I–III, air, dry biogas and dry recycled gases, subject to verified material compatibility |
| Hydrogen Sulfide (H2S) Limit | 1% by volume under dry gas conditions |
| Ammonia (NH3) Limit | 1% by volume under dry gas conditions |
| Built-in Particle Strainer | VRF10: Stainless steel, 0.9 mm mesh opening |
| Supported Actuator Families | Siemens SKP Series; SKL and SAX31 subject to application restrictions |
| Valve Model | Connection Size | Maximum Pressure (mbar) | Air Flow Rate (m³/h) |
|---|---|---|---|
| VRF10.404 | DN40 | 600 | 125 |
| VRF10.504 | DN50 | 600 | 190 |
| VRF10.654 | DN65 | 600 | 280 |
| VRF10.804 | DN80 | 600 | 350 |
| VRH10.805 | DN80 | 300 | 400 |
| VRH10.905 | DN100 | 300 | 790 |
| VRH10.915 | DN125 | 250 | 1200 |
Technical Note: The listed air flow rates are measured at a pressure differential of Δp = 10 mbar and must not be interpreted as maximum flow capacities for every operating condition. Source document: Siemens Data Sheet CC1N7633en.
| Brand / Manufacturer | Siemens |
|---|---|
| Valve Series | VRF10 / VRH10 |
| Equipment Category | Valves for Biogas and Recycled Gas Applications |
| Operating Configuration | Two-port, Normally Closed |
| Safety Classification | Class A under EN 161 when paired with approved suitable actuators |
| EN 161 Valve Group | Group 2 (EN 161) |
| VRF10 Connection Range | DN40–DN80 |
| VRH10 Connection Range | DN80–DN125 |
| VRF10 Maximum Operating Pressure | Up to 600 mbar |
| VRH10 Permitted Operating Pressure | 250–300 mbar, model-dependent |
| Allowable Gas Temperature | 0 to +60°C |
| Ambient Working Temperature | -10 to +60°C |
| Permissible Storage Temperature | -20 to +60°C |
| Permissible Transport Temperature | -15 to +60°C |
| Humidity Limit | Below 95% RH; condensation is prohibited |
| Flange Pressure Rating | PN16 in accordance with ISO 7005-2 |
| Permitted Gas Categories | Gas Families I–III, air, dry biogas and dry recycled gases, subject to verified material compatibility |
| Hydrogen Sulfide (H2S) Limit | 1% by volume under dry gas conditions |
| Ammonia (NH3) Limit | 1% by volume under dry gas conditions |
| Built-in Particle Strainer | VRF10: Stainless steel, 0.9 mm mesh opening |
| Supported Actuator Families | Siemens SKP Series; SKL and SAX31 subject to application restrictions |
| Valve Model | Connection Size | Maximum Pressure (mbar) | Air Flow Rate (m³/h) |
|---|---|---|---|
| VRF10.404 | DN40 | 600 | 125 |
| VRF10.504 | DN50 | 600 | 190 |
| VRF10.654 | DN65 | 600 | 280 |
| VRF10.804 | DN80 | 600 | 350 |
| VRH10.805 | DN80 | 300 | 400 |
| VRH10.905 | DN100 | 300 | 790 |
| VRH10.915 | DN125 | 250 | 1200 |
Technical Note: The listed air flow rates are measured at a pressure differential of Δp = 10 mbar and must not be interpreted as maximum flow capacities for every operating condition. Source document: Siemens Data Sheet CC1N7633en.
บริษัท บุญเยี่ยมและสหาย จำกัด