Siemens LMV27 Series is a microprocessor-based burner management system designed for the control and supervision of medium- to high-capacity forced draft burners. It supports single-fuel gas or oil burners operating in intermittent mode.
The LMV27 integrates burner sequence control, flame supervision, electronic fuel/air ratio control, and gas valve proving into one burner management platform. The system supports up to two actuators for coordinated combustion control.
Siemens LMV27 is intended for OEM manufacturers and qualified burner system integrators. Typical applications include:
Note: Component selection, parameter settings, and system commissioning must follow the applicable Siemens technical documentation and be performed by qualified personnel.
| Brand | Siemens |
|---|---|
| Product Series | LMV27 Series |
| Reference Model | LMV27.100A2 |
| Product Type | Burner Management System |
| Control Technology | Microprocessor-based |
| Fuel Type | Gas / Oil (Single-fuel Burner) |
| Operating Mode | Intermittent Operation |
| Supply Voltage | AC 230 V (-15% / +10%) |
| Frequency | 50 / 60 Hz ±6% |
| Power Consumption | <30 W (Typical) |
| Fuel/Air Ratio Control | Electronic |
| Maximum Actuators | 2 |
| Compatible Actuators | SQM3... / SQN1... |
| Gas Valve Proving | Integrated |
| Flame Detectors | QRA2 / QRA4 / QRA10 / QRB / QRC / Ionization Probe |
| Safety Time (Gas) | 3 seconds |
| Safety Time (Oil) | 5 seconds |
| Communication | Modbus / BCI |
| Display Units | AZL21 / AZL23 |
| Configuration Software | Siemens ACS410 |
| Protection Rating | IP00 (Basic Unit) |
| Operating Temperature | -20 to +60 °C |
| Relative Humidity | <95% RH (Non-condensing) |
| Internal Fuse | 6.3 AT |
| Maximum External Fuse | 16 AT |
| Test Standards | EN 230, EN 298, EN 1643, EN 12067-2, EN 13611 |
Technical information is based on Siemens Datasheet CC1N7541en for LMV27.100A2. Installation must follow Siemens requirements. The burner or boiler manufacturer must provide IP40 protection through suitable installation.
| Brand | Siemens |
|---|---|
| Product Series | LMV27 Series |
| Reference Model | LMV27.100A2 |
| Product Type | Burner Management System |
| Control Technology | Microprocessor-based |
| Fuel Type | Gas / Oil (Single-fuel Burner) |
| Operating Mode | Intermittent Operation |
| Supply Voltage | AC 230 V (-15% / +10%) |
| Frequency | 50 / 60 Hz ±6% |
| Power Consumption | <30 W (Typical) |
| Fuel/Air Ratio Control | Electronic |
| Maximum Actuators | 2 |
| Compatible Actuators | SQM3... / SQN1... |
| Gas Valve Proving | Integrated |
| Flame Detectors | QRA2 / QRA4 / QRA10 / QRB / QRC / Ionization Probe |
| Safety Time (Gas) | 3 seconds |
| Safety Time (Oil) | 5 seconds |
| Communication | Modbus / BCI |
| Display Units | AZL21 / AZL23 |
| Configuration Software | Siemens ACS410 |
| Protection Rating | IP00 (Basic Unit) |
| Operating Temperature | -20 to +60 °C |
| Relative Humidity | <95% RH (Non-condensing) |
| Internal Fuse | 6.3 AT |
| Maximum External Fuse | 16 AT |
| Test Standards | EN 230, EN 298, EN 1643, EN 12067-2, EN 13611 |